RH Peterson Real-Fyre G4516/1917N 16/19" Triple T Vented Burner with Automatic Pilot / Variable Flame - Natural Gas

Sku:
RH-PETERSON-G4516/1917N
Usually Leaves Warehouse in 2 - 3 Business Days
$918.90
Burners are certified to work with SPECIFIC Log Sets only. While there may be several allowable Log Sets for a specific burner, they are NOT universal. Using a burner with a non-compatible log set can lead to Fire, Carbon Monoxide Poisoning and Property Damage.
The G45 burner is a Triple T Burner. It consists of a main burner tube that extends down the middle and a smaller front flame burner that "T"s off the main burner. The additional front flame allows you to position the burner directly beneath the logs helping to accentuate the front flame. This specialized burner also gives you a nice bed of glowing embers under beautiful dancing flames. With its front pipe, there are three additional spaces for the flames to come through, adding more depth to your fire. The G45 burner, regardless of the pilot valve chosen, will still give you dancing flames across the length of the burner tubes and your glowing embers will glow nicely, for a more realistic fire.
 
The G45 Burner system includes:
  • Burner pan
  • Grate
  • Glowing embers
  • Sand
  • Burner clips
  • Flex connector kit
  • Damper clamp
  • APK-17 variable flame remote control safety pilot system included with burner
The APK-17 is a variable flame remote control safety pilot system which features a Low profile adjustable flame remote control safety pilot that takes up less room and requires less clearance inside your fireplace. It uses a standing pilot that stays lit. As long as the safety pilot is lit, the burner can be turned on or off and the flame height can be adjusted by remote or manually. The APK-17 includes VR-1 On/Off remote transmitter that actually adjusts the flame height as well.
 
You can upgrade to VR-2 Deluxe Remote Control system with Thermostat, Timer, Clock and Room Temperature (sold separately).
 
Log set is sold separately.
 
Burner ModelMinimum Fireplace SizeBTU Ratings
Width*DepthHeightNGLP
FrontRear
G45-16/19  29" 22" 11" 17" 40k 30k
G45-18/20  30" 24" 13" 17" 70k 45k
G45-24  34" 28" 13" 17" 90K 65k
G45-30  40" 34" 16" 17" 95k 75k
G45-36  46" 40" 16" 17" 110k 90k
       
*The required widths allow for centering of the unit within the fireplace. For G45-**-02 models, add 2" to both the front and rear width. Depth requirements begin inside the ash lip if one exists.
FREE SHIPPING ON ALL ORDERS!
RH Peterson Real-Fyre G4516/19N 16/19" Triple T Vented Burner with APK17 Automatic Pilot - Natural Gas
  • RH Peterson Real-Fyre G4516/19N 16/19" Triple T Vented Burner with APK17 Automatic Pilot - Natural Gas
  • RH Peterson Real-Fyre G4516/1917N 16/19" Triple T Vented Burner with  Automatic Pilot / Variable Flame - Natural Gas
  • RH Peterson Real-Fyre G4516/1917N 16/19" Triple T Vented Burner with  Automatic Pilot / Variable Flame - Natural Gas

Product Overview

Burners are certified to work with SPECIFIC Log Sets only. While there may be several allowable Log Sets for a specific burner, they are NOT universal. Using a burner with a non-compatible log set can lead to Fire, Carbon Monoxide Poisoning and Property Damage.
The G45 burner is a Triple T Burner. It consists of a main burner tube that extends down the middle and a smaller front flame burner that "T"s off the main burner. The additional front flame allows you to position the burner directly beneath the logs helping to accentuate the front flame. This specialized burner also gives you a nice bed of glowing embers under beautiful dancing flames. With its front pipe, there are three additional spaces for the flames to come through, adding more depth to your fire. The G45 burner, regardless of the pilot valve chosen, will still give you dancing flames across the length of the burner tubes and your glowing embers will glow nicely, for a more realistic fire.
 
The G45 Burner system includes:
  • Burner pan
  • Grate
  • Glowing embers
  • Sand
  • Burner clips
  • Flex connector kit
  • Damper clamp
  • APK-17 variable flame remote control safety pilot system included with burner
The APK-17 is a variable flame remote control safety pilot system which features a Low profile adjustable flame remote control safety pilot that takes up less room and requires less clearance inside your fireplace. It uses a standing pilot that stays lit. As long as the safety pilot is lit, the burner can be turned on or off and the flame height can be adjusted by remote or manually. The APK-17 includes VR-1 On/Off remote transmitter that actually adjusts the flame height as well.
 
You can upgrade to VR-2 Deluxe Remote Control system with Thermostat, Timer, Clock and Room Temperature (sold separately).
 
Log set is sold separately.
 
Burner ModelMinimum Fireplace SizeBTU Ratings
Width*DepthHeightNGLP
FrontRear
G45-16/19  29" 22" 11" 17" 40k 30k
G45-18/20  30" 24" 13" 17" 70k 45k
G45-24  34" 28" 13" 17" 90K 65k
G45-30  40" 34" 16" 17" 95k 75k
G45-36  46" 40" 16" 17" 110k 90k
       
*The required widths allow for centering of the unit within the fireplace. For G45-**-02 models, add 2" to both the front and rear width. Depth requirements begin inside the ash lip if one exists.

Tech Specs

General Features

Fireplace Style:
Single Sided
Type of Venting:
Vented
Location of Use:
Indoor
Media Style:
Traditional Log Set
Type of Grate:
Standard
Fuel Type:
Natural Gas (NG)
Allowable Log Set Sizes (in.):
16" / 19"
Allowable Log Sets:
Real-Fyre Gas Log Set Not Included
Certified Usage:
Mobile Home Approved

Performance

BTUs (Max.):
40000
Ignition Type:
Electronic Ignition
Remote:
Variable Flame Remote Included

Gas Requirements

Gas Connection Size (in.):
1/2"
Manifold Pressure (in.):
NA
Inlet Gas Pressure (Min.):
5.0" w.c.
Inlet Gas Pressure (Max.):
10.5" w.c.

Minimum Firebox Requirements

Requirements for 16" or 19" Logs

Req. Min. Front Width (in.):
29"
Req. Min. Rear Width (in.):
22"
Req. Min. Depth (in.):
11"
Req. Min. Height (in.):
17"
Chimney Height (Min. ft.):
15'
California residents see Prop 65 WARNINGS

Warning WARNING!