null

Daikin DACA-CP3-1 230 Volt Mini Condensate Removal Pump

Sku:
DAIKIN-DACACP31
Usually Leaves Warehouse in 2 - 3 Business Days
$209.00
A condensate removal pump is used when gravity cannot route the condensation build-up from your air conditioner properly. The condensation is collected in the pump and routed through a tube to the drainage point, whether it is a sewer, a floor drain, a window or even through the wall and outside.

The high performance DACA-CP3-1 has been engineered in partnership with and manufactured to Daikin specifications. It is for use with Daikin models up to 42000 BTUs including single and multi-zone indoor units as well as specific SkyAir units.
  • Daikin Indoor Units
  • FTXS09LVJU, FTXS12LVJU, FTXS15LVJU, FTXS18LVJU, FTXS24LVJU, FTXS30LVJU, FTXS36LVJU
  • FTXN09KVJU, FTXN12KEVJU
  • FTXN15KVJU, FTXN18KVJU, FTXN24KVJU
  • FTXG09HVJU, FTXG12HVJU, FTXG15HVJU
  • CTXS07HVJU, CTXS09HVJU, CTXS12HVJU
  • CTXS007LVJU
  • FDXS09DVJU, FDXS12DVJU
  • FDXS09LVJU, FDXS12LVJU
  • CDXS15LVJU, CDXS18LVJU
  • SkyAir Indoor Units:
  • FTXS30LVJU, FTXS36LVJU
  • FHQ18PVJU, FHQ24PVJU, FHQ30PVJU,
  • FHQ36MVJU, FHQ42MVJU
  • FAQ18PVJU, FAQ24PVJU
  • VRV Indoor Units:
  • FXHQ12MVJU, FXHQ24MVJU, FXHQ36MVJU
  • FXLQ12MVJU, FXLQ18MVJU, FXLQ24MVJU
  • FXNQ12MVJU, FXNQ18MVJU, FXNQ24MVJU
  • FXAQ07PVJU, FXAQ09PVJU, FXAQ12PVJU, FXAQ18PVJU, FXAQ24PVJU
 
It is suitable for air-conditioning units up to 3.5 tons. The piston technology is specifically designed for removing condensates from air conditioning systems. The Si-30 is fully reliable, in any kind of environment. Its operating sound level will remain silent whatever the volume of condensates. It also boasts a low noise level (20 dBA) and small size with a low maintenance filter-free detection system.

 

This mini pump can be used with air conditioners up to 5.6 tons (67 kBTU - 20 kW), wall split systems, consoles, fan coils, ceiling suspended units and ducted units.

  • High resistance to pollution created by general environment. Capable of discharging small particles
  • Proven reliability
  • Silent
    • Quiet in operation: 20 dBA independently tested.
    • The size of the air-conditioning unit and volume of condensates to be removed does not affect the operational sound level of the pump.
    • New mounting bracket specifically designed to reduce vibration transmission to the wall / panel or pipework
  • Easy to install
    • Compact design
    • New mounting bracket : allows the pump to be wall mounted or hung from ceilings and pipework
    • Plug-in power cord to make maintenance and replacement hassle free
  • Energy saving
    • Improved performance and high flow rate reduce operation time and energy
  • Kit Includes:
    • Piston pump
    • Anti-vibration mounting bracket
    • Plug in power cable with 2 safety switch wires (5ft - 1,5 m)
    • 6 tie wraps, 1/10" x 4" (2.5 x 100mm)
    • Detection unit SI2958, with (5 ft - 1.5m) cable
    • Detection unit installation kit: rubber elbow 90° Øint. 19/32" x 2"3/8 (Øint. 15 x L 60mm), Vent tube Øint. 5/32" x L 2"15/16 (Øint. 4 x L 75 mm), mounting rail, adhesive
    • TECHNICAL SPECIFICATION
      • Max. flow rate 5.0 gph (19 l/h)
      • Max. suction head 10 ft (3 m)
      • Max. discharge head 33ft (10 m); flow rate= 1gph (4l/h)
      • Max pressure 46 ft (14 m); flow rate = 0 gph (0l/h)
      • Sound level at 1m according to EN ISO 3744 (Measured at LNE lab, pump operating with water, out of application) 20 dBA
      • Sound level in application at 1m: (Measured in Sauermann acoustic lab, pump operating with water) ≤ 27 dBA
      • Mains supply 120V ~ 60 Hz - 14 W (SI3000SIUS11) 230 V ~ 50/60 Hz - 14 W (SI3000SIUS23)
      • Insulation class (double insulation)
      • Detection levels On=5/8” Off=7/16’’ Alarm=3/4’’ (ON: 16mm, OFF: 11mm, AL: 19mm)
      • Safety switch NC 8A resistive - 250 V
      • Thermal protection (overheating) 194°F (90°C) auto-reset
      • Intermittent operation cycle 30%: 3s ON – 7s OFF
      • Protection IP20
      • Safety standards UL/CSA certified by Intertek
      • RoHS directive Compliant
      • DEEE directive Compliant
      Dimensions:
      • Pump Unit: 2 5/8"L x 1 3/4" W x 2 3/8"H
      • Detection Unit: 2 1/4"L x 1 1/2"W x 1` 1/2"H
FREE SHIPPING ON ALL ORDERS!
Daikin DACA-CP3-1 230 Volt Mini Condensate Removal Pump

Product Overview

A condensate removal pump is used when gravity cannot route the condensation build-up from your air conditioner properly. The condensation is collected in the pump and routed through a tube to the drainage point, whether it is a sewer, a floor drain, a window or even through the wall and outside.

The high performance DACA-CP3-1 has been engineered in partnership with and manufactured to Daikin specifications. It is for use with Daikin models up to 42000 BTUs including single and multi-zone indoor units as well as specific SkyAir units.
  • Daikin Indoor Units
  • FTXS09LVJU, FTXS12LVJU, FTXS15LVJU, FTXS18LVJU, FTXS24LVJU, FTXS30LVJU, FTXS36LVJU
  • FTXN09KVJU, FTXN12KEVJU
  • FTXN15KVJU, FTXN18KVJU, FTXN24KVJU
  • FTXG09HVJU, FTXG12HVJU, FTXG15HVJU
  • CTXS07HVJU, CTXS09HVJU, CTXS12HVJU
  • CTXS007LVJU
  • FDXS09DVJU, FDXS12DVJU
  • FDXS09LVJU, FDXS12LVJU
  • CDXS15LVJU, CDXS18LVJU
  • SkyAir Indoor Units:
  • FTXS30LVJU, FTXS36LVJU
  • FHQ18PVJU, FHQ24PVJU, FHQ30PVJU,
  • FHQ36MVJU, FHQ42MVJU
  • FAQ18PVJU, FAQ24PVJU
  • VRV Indoor Units:
  • FXHQ12MVJU, FXHQ24MVJU, FXHQ36MVJU
  • FXLQ12MVJU, FXLQ18MVJU, FXLQ24MVJU
  • FXNQ12MVJU, FXNQ18MVJU, FXNQ24MVJU
  • FXAQ07PVJU, FXAQ09PVJU, FXAQ12PVJU, FXAQ18PVJU, FXAQ24PVJU
 
It is suitable for air-conditioning units up to 3.5 tons. The piston technology is specifically designed for removing condensates from air conditioning systems. The Si-30 is fully reliable, in any kind of environment. Its operating sound level will remain silent whatever the volume of condensates. It also boasts a low noise level (20 dBA) and small size with a low maintenance filter-free detection system.

 

This mini pump can be used with air conditioners up to 5.6 tons (67 kBTU - 20 kW), wall split systems, consoles, fan coils, ceiling suspended units and ducted units.

  • High resistance to pollution created by general environment. Capable of discharging small particles
  • Proven reliability
  • Silent
    • Quiet in operation: 20 dBA independently tested.
    • The size of the air-conditioning unit and volume of condensates to be removed does not affect the operational sound level of the pump.
    • New mounting bracket specifically designed to reduce vibration transmission to the wall / panel or pipework
  • Easy to install
    • Compact design
    • New mounting bracket : allows the pump to be wall mounted or hung from ceilings and pipework
    • Plug-in power cord to make maintenance and replacement hassle free
  • Energy saving
    • Improved performance and high flow rate reduce operation time and energy
  • Kit Includes:
    • Piston pump
    • Anti-vibration mounting bracket
    • Plug in power cable with 2 safety switch wires (5ft - 1,5 m)
    • 6 tie wraps, 1/10" x 4" (2.5 x 100mm)
    • Detection unit SI2958, with (5 ft - 1.5m) cable
    • Detection unit installation kit: rubber elbow 90° Øint. 19/32" x 2"3/8 (Øint. 15 x L 60mm), Vent tube Øint. 5/32" x L 2"15/16 (Øint. 4 x L 75 mm), mounting rail, adhesive
    • TECHNICAL SPECIFICATION
      • Max. flow rate 5.0 gph (19 l/h)
      • Max. suction head 10 ft (3 m)
      • Max. discharge head 33ft (10 m); flow rate= 1gph (4l/h)
      • Max pressure 46 ft (14 m); flow rate = 0 gph (0l/h)
      • Sound level at 1m according to EN ISO 3744 (Measured at LNE lab, pump operating with water, out of application) 20 dBA
      • Sound level in application at 1m: (Measured in Sauermann acoustic lab, pump operating with water) ≤ 27 dBA
      • Mains supply 120V ~ 60 Hz - 14 W (SI3000SIUS11) 230 V ~ 50/60 Hz - 14 W (SI3000SIUS23)
      • Insulation class (double insulation)
      • Detection levels On=5/8” Off=7/16’’ Alarm=3/4’’ (ON: 16mm, OFF: 11mm, AL: 19mm)
      • Safety switch NC 8A resistive - 250 V
      • Thermal protection (overheating) 194°F (90°C) auto-reset
      • Intermittent operation cycle 30%: 3s ON – 7s OFF
      • Protection IP20
      • Safety standards UL/CSA certified by Intertek
      • RoHS directive Compliant
      • DEEE directive Compliant
      Dimensions:
      • Pump Unit: 2 5/8"L x 1 3/4" W x 2 3/8"H
      • Detection Unit: 2 1/4"L x 1 1/2"W x 1` 1/2"H

Tech Specs

Product Type:
Pump
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov