null

ICM UDEFROST Universal Defrost Control Module / Board

Sku:
ICM-UDEFROST
In Stock, Ships Next Business Day
$82.65
The UDEFROST Universal Defrost Control Module / Board is a single defrost control board that replaces almost all time/temperature heat pump defrost boards.  
  • Universal time & temperature defrost board for heat pumps
  • Configurable settings with NFC
    • Compressor anti-short cycle delay
    • High ambient temperature auxiliary heat lockout
    • Low ambient temperature compressor lockout
    • Defrost end & defrost enable temperature
    • Defrost interval timer
    • Max defrost time
    • Quiet shift
    • Compressor staging delay (after brownout or at power-up)
    • Heat active/cool active reversing valve configuration
  • Field test mode
  • Brownout protection
  • LED indicators to aid in troubleshooting

Specifications:

Inputs:
  • Power Supply: R, C (24VAC, 50/60 Hz)
  • Thermostat: 24VAC, 24mA
  • Low-Pressure Switch (LPS): 24VAC
  • High-Pressure Switch (HPS): 24VAC
  • Outdoor Ambient Thermistor (OAT): 10K ohm
  • Outdoor Coil Sensor (OCT): 10K ohm
  • Field Test Button
Outputs:
  • Fan: N.C. ; 1/2HP, (2.7 FLA), 240 VAC
  • Compressor Contactor: 24VAC, 1A, Pilot Duty
  • Reversing Valve (O/B): 24VAC, 1A, Pilot Duty
  • W2: 24VAC, 1A, Pilot Duty
Environment:
  • Operating Ambient Temperature: -40 C to 70 C
  • Shipping and Storage Temperature: -40 C to 75 C

Dimensions:

  • 3.75"h x 2"w x 5.5"l

Replaces: all legacy ICM Controls defrost boards. Please see Cross Reference Guide attached under Manuals and Guides.

FREE SHIPPING ON ALL ORDERS!
ICM UDEFROST Universal Defrost Control Module / Board

Product Overview

The UDEFROST Universal Defrost Control Module / Board is a single defrost control board that replaces almost all time/temperature heat pump defrost boards.  
  • Universal time & temperature defrost board for heat pumps
  • Configurable settings with NFC
    • Compressor anti-short cycle delay
    • High ambient temperature auxiliary heat lockout
    • Low ambient temperature compressor lockout
    • Defrost end & defrost enable temperature
    • Defrost interval timer
    • Max defrost time
    • Quiet shift
    • Compressor staging delay (after brownout or at power-up)
    • Heat active/cool active reversing valve configuration
  • Field test mode
  • Brownout protection
  • LED indicators to aid in troubleshooting

Specifications:

Inputs:
  • Power Supply: R, C (24VAC, 50/60 Hz)
  • Thermostat: 24VAC, 24mA
  • Low-Pressure Switch (LPS): 24VAC
  • High-Pressure Switch (HPS): 24VAC
  • Outdoor Ambient Thermistor (OAT): 10K ohm
  • Outdoor Coil Sensor (OCT): 10K ohm
  • Field Test Button
Outputs:
  • Fan: N.C. ; 1/2HP, (2.7 FLA), 240 VAC
  • Compressor Contactor: 24VAC, 1A, Pilot Duty
  • Reversing Valve (O/B): 24VAC, 1A, Pilot Duty
  • W2: 24VAC, 1A, Pilot Duty
Environment:
  • Operating Ambient Temperature: -40 C to 70 C
  • Shipping and Storage Temperature: -40 C to 75 C